All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Perform gravimetric analyses |
SAQA US ID | UNIT STANDARD TITLE | |||
246451 | Perform gravimetric analyses | |||
ORIGINATOR | ||||
Chemical Industries SGB | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 4 | NQF Level 04 | 6 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
This unit standard is intended for a person who has to perform gravimetric analyses in a laboratory environment.
A person credited with this unit standard is able to: This unit standard will contribute to the full development of the learner by providing recognition, further mobility and transportability within the sub-fields of manufacturing and assembly, physical sciences, life sciences, environmental sciences, earth and space sciences. The skills, knowledge and understanding demonstrated within this unit standard are essential for social and economic transformation and upliftment within the manufacturing and processing environment. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
Description of required skills:
|
UNIT STANDARD RANGE |
For the purposes of this unit standard at least five of the following range of gravimetric analyses should be included:
|
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Demonstrate an understanding of gravimetric analyses in a laboratory environment. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The importance of performing the specific gravimetric analysis is explained according to standard chemical and quality control principles. |
ASSESSMENT CRITERION 2 |
The principles of gravimetric analyses are explained according to standard chemical principles. |
ASSESSMENT CRITERION 3 |
The whole range of gravimetric analyses are described in terms of the equipment and reagents (where relevant) required for each test. |
ASSESSMENT CRITERION 4 |
The procedures for at least five different types of gravimetric analyses are described according to standard operating procedures and with reference to the reasons for each step in the procedure. |
SPECIFIC OUTCOME 2 |
Prepare for gravimetric analyses. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Preparations for each analysis is done according to workplace procedures. |
ASSESSMENT CRITERION 2 |
Safety preparations and personal protective equipment are applied as required by safety procedures for each analysis. |
ASSESSMENT CRITERION 3 |
Work area and equipment preparations (including cleaning and calibration of instruments where applicable) are done as required by the procedures for each analysis. |
ASSESSMENT CRITERION 4 |
Preparation of reagents (where applicable) are done as required by each analysis procedure. |
ASSESSMENT CRITERION 5 |
Preparation of samples is done as required by each analysis. |
SPECIFIC OUTCOME 3 |
Perform gravimetric analyses. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Each specific analysis are performed according to standard operating procedures and scientific principles. |
ASSESSMENT CRITERION 2 |
Equipment, samples and reagents (where applicable) are handled according to standard operating procedures and safety precautions. |
ASSESSMENT CRITERION 3 |
Test results are established without error and according to standard operating procedures. |
ASSESSMENT CRITERION 4 |
The importance of accurate results is explained according to standard principles of quality control and assurance. |
ASSESSMENT CRITERION 5 |
The equipment and work area is left in a safe, neat and clean condition after performing the tests. |
ASSESSMENT CRITERION 6 |
Waste from the analysis is handled according to standard operating procedures and the organisation's environmental policy. |
SPECIFIC OUTCOME 4 |
Report on the results of the gravimetric analyses. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Analysis test results are calculated (where applicable) and recorded according to standard operating procedures. |
ASSESSMENT CRITERION 2 |
The specifications/limits for each test are identified as set by the organisation or current legislation. |
ASSESSMENT CRITERION 3 |
Test results are evaluated and interpreted and a conclusion is drawn on the conformance to set specifications/limits. |
ASSESSMENT CRITERION 4 |
Deviations from specifications/limits are explained according to standard scientific principles. |
ASSESSMENT CRITERION 5 |
Test results are reported according to standard operating procedures. |
ASSESSMENT CRITERION 6 |
The importance of accurate records and reports is explained according to standard principles of quality control and assurance. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
The qualifying learner understands and is able to:
|
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems in which response displays that responsible decisions, using critical and creative thinking, have been made by:
Refer to the following Specific Outcome(s): |
UNIT STANDARD CCFO WORKING |
Work effectively with others as a member of a team, group, organisation or community by:
Refer to the following Specific Outcome(s): |
UNIT STANDARD CCFO ORGANISING |
Organise and manage oneself and one's activities responsibly and effectively by:
Refer to the following Specific Outcome(s): |
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information:
Refer to the following Specific Outcome(s): |
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively by using mathematical and/or language skills in the modes of oral and/or written presentations by:
Refer to the following Specific Outcome(s): |
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically, showing responsibility towards the environment and health of others by:
Refer to the following Specific Outcome(s): |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems by recognising that problem-solving contexts do not exist in isolation by:
Refer to all Specific Outcomes. |
UNIT STANDARD CCFO CONTRIBUTING |
Contribute to the full personal development of each learner and the social and economic development of the society at large by:
Refer to all Specific Outcomes. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
Terms and definitions and notes to the assessor:
Basic gravimetric analysis contains those basic procedures for which the final measurement is a weighing: Standard operating procedures: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 64950 | Further Education and Training Certificate: Laboratory Analysis | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | As per Learning Programmes recorded against this Qual |
Core | 58952 | Further Education and Training Certificate: Laboratory Analysis | Level 4 | NQF Level 04 | Passed the End Date - Status was "Registered" |
2008-08-05 | As per Learning Programmes recorded against this Qual |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |