All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Replace a 3-phase electrical motor between 5,5 kW and 75 kW |
SAQA US ID | UNIT STANDARD TITLE | |||
10649 | Replace a 3-phase electrical motor between 5,5 kW and 75 kW | |||
ORIGINATOR | ||||
SGB Mining and Minerals | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Fabrication and Extraction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 3 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Registered" |
2002-08-14 | 2005-08-14 | SAQA 0443/02 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2006-08-14 | 2009-08-14 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
This unit standard will be useful to people who are required to replace an electrical motor.
People credited with this unit standard are able to: |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
The credit calculation is based on the assumption that learners are already competent in terms of the following outcomes or areas of learning when starting to learn towards this unit standard:
|
UNIT STANDARD RANGE |
Specific range statements are provided in the body of the unit standard where they apply to particular specific outcomes or assessment criteria. |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Describe the requirements pertaining to the replacing, handling and securing of motors. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1.The requirement in terms of the selection of a motor is explained in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
2. The requirement in terms of the securing of a motor is explained in accordance with specified requirements. |
ASSESSMENT CRITERION 3 |
3. The requirement in terms of testing a motor is explained in accordance with specified requirements. |
ASSESSMENT CRITERION 4 |
4. The requirement in terms of the storage of a motor is explained in accordance with specified requirements. |
SPECIFIC OUTCOME 2 |
Prepare to replace the motor. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Personal protective equipment is examined and used in a manner that protects the individual in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
2. Tools, material and equipment are selected and transported in accordance with specified requirements. |
ASSESSMENT CRITERION 3 |
3. Permission to enter the workplace where applicable is obtained in accordance with specified requirements. |
ASSESSMENT CRITERION 4 |
4. The replacement motor is selected and tested for faults prior to replacement and corrective action is taken in accordance with specified requirements. |
ASSESSMENT CRITERION 5 |
5. The workplace is examined for hazardous and sub-standard conditions. Critical hazards and sub-standard conditions encountered in a particular context are addressed in a manner consistent with documented best practice. |
ASSESSMENT CRITERION 6 |
6. The consequences of not preparing for replacement in line with specified requirements are explained with reference to personal and team safety, impact on the environment, production costs and lost time. |
SPECIFIC OUTCOME 3 |
Replace the motor. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Hazards and risks directly related to the replacement of the motor are identified and addressed in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
2. The power supply is switched off and lockout procedures are adhered to in accordance with specified requirements. |
ASSESSMENT CRITERION 3 |
3. The motor is replaced in accordance with specified requirements. |
ASSESSMENT CRITERION 4 |
4. Interpersonal interaction is positive, consistent with specified requirements, promotes effective teamwork and avoids dysfunctional conflict. |
ASSESSMENT CRITERION 5 |
5. The consequences of not installing the motor in line with specified requirements are explained with reference to personal and team safety, impact on the environment, production costs and lost time. |
SPECIFIC OUTCOME 4 |
Prepare and test for operation. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. The power is switched on in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
2. The equipment is tested for functional operation in accordance with specified requirements. |
ASSESSMENT CRITERION 3 |
3. Tools, material and equipment are cleaned, inspected and stored in accordance with specified requirements. |
ASSESSMENT CRITERION 4 |
4. The workplace is cleaned to comply with specified good housekeeping requirements. |
ASSESSMENT CRITERION 5 |
5. The feedback report complies with specified requirements for format, content, accuracy and distribution. The report is delivered within the agreed time. |
ASSESSMENT CRITERION 6 |
6. The consequences of not preparing and testing the equipment for operation in line with specified requirements are explained with reference to personal and team safety, impact on the environment, production costs and lost time. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
1. Anyone assessing a learner against this unit standard must be registered as an assessor with the relevant ETQA.
2. Any institution offering learning that will enable achievement of this unit standard must be accredited as a provider through the relevant ETQA by SAQA. 3. Moderation of assessment will be overseen by the relevant ETQA according to the moderation guidelines and the agreed ETQA procedures. |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
Essential embedded knowledge will be assessed through assessment of the specific outcomes in terms of the stipulated assessment criteria. Candidates are unlikely to achieve all the specific outcomes, to the standards described in the assessment criteria, without knowledge of the listed embedded knowledge. This means that for the most part, the possession or lack of the knowledge can be directly inferred from the quality of the candidate`s performance. Where direct assessment of knowledge is required, assessment criteria have been included in the body of the unit standard.
The following embedded knowledge is addressed in an integrated way in the unit standard: |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems and make decisions using critical and creative thinking.
Note: The ability of the candidate to identify sub-standard and hazardous conditions, assess and take appropriate action. |
UNIT STANDARD CCFO WORKING |
Work effectively with others as members of a team, group, organisation or community.
Note: The ability and willingness of the candidate to accept and interpret work instructions correctly. |
UNIT STANDARD CCFO ORGANISING |
Organise and manage themselves and their activities responsibly and effectively.
Note: The ability of the candidate to indicate what methods, tools and personal protective equipment is required and communicate to fellow workers his / her intentions and assistance required. |
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information.
Note: The ability of the candidate to reconcile the information from visual and physical examinations and constantly evaluate the changing situation. |
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively, using visual, mathematical and / or language skills in the modes of oral and / or written presentations.
Note: The appropriate communication with the relevant personnel with regard to the reporting of hazards and sub-standard conditions will indicate his / her proficiency in effective communication. |
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically showing responsibility towards the environment and health of others.
Note: The use of science and technology is not relevant for this unit standard. |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems by recognising that problem-solving contexts do not exist in isolation.
Note: The ability of the candidate to identify and refer anomalous behaviour to a specialist confirms understanding that a specific observation, inference, action or decision can have a devastating effect. |
UNIT STANDARD NOTES |
SPECIFIED REQUIREMENTS
Specified requirements include legal and site-specific requirements and are contained in one or more of the following documents: LEGAL SITE SPECIFIC NOTES TO ASSESSORS: Assessors should keep the following principles in mind when designing and conducting assessments against this unit standard: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 20420 | National Certificate: Electrical Engineering | Level 4 | NQF Level 04 | Passed the End Date - Status was "Registered" |
2004-02-10 | Was EWSETA until Last Date for Achievement |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |